Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Restore the pulse shape used before #15209 for CFD timing and scalar amplitude integration. The SIMD amplitude integration was already using the previous pulse shape. This change makes all three calculations use the same pulse model.
FT0 pulse-shape validation
All three runs used the same 1,000 simulated collisions. Mean summed amplitudes were calculated over the same 950 FT0 bunch crossings. The timing comparison includes entries where both side times are within ±10 ns.
t_A(ps)t_C(ps)t_C − t_A(ps)t_C − t_A(ps)At fixed crosstalk, restoring the old pulse lowers the mean summed amplitude by 0.34% on A and 0.36% on C. Both mean side times shift earlier by about 55 ps.
With the old pulse, enabling crosstalk increases the mean summed amplitude by 15.00% on A and 5.13% on C. The mean
t_C − t_Ashifts by +1.61 ps, and its standard deviation changes by less than 0.04 ps.The restored pulse shifts the mean trigger time on both sides earlier by about 55 ps.Follow-up
We will work on reintroducing the new pulse shape consistently throughout the FT0 digitizer, including CFD timing and both scalar and SIMD amplitude integration.